TSS in dewatering centrate (with screen and buttons)

OTD-SDWB

OTD-SDWB-00X

TSS in dewatering centrate (Inline mounting)

TSS in centrate.
Pre-calibrated sensor with sample grabber and flow-cell.

Go to Shop
TSS in dewatering centrate (Inline mounting)

Measurement

TSS Measurement in Centrate, with superior fouling resistance.  

Thanks to the sample grabber and flow-cell, the sensor provides and end-to-end measurement solution. 


The polymer content in the water leads to a strong tendency for fouling which is where ultrasound sensors are superior.  Olpas TSS sensors are therefor suitable for use in filtrate or centrate of dewatering installations. 


Get in touch to discuss your particular ciscumstances.  


(bio-)fouling and oily medium

Superior resistance to (bio-)fouling. 

The presence of oily or greasy materials does not hinder the measurement as the ultrasound pulse can penetrate such depositions on the sensor surface.


Impact of changes in temperature

Independent of temperature of the medium or the sensor. 


Air bubbles

The sensor is also available for usage in centrate with large amounts of finely dispersed air bubbles.

Usage of the sensor in degassed centrate, improves the resolution of the sensor.


Get in touch to discuss the specific parameters of your installation. 




Installation

Requirements

Free depth of +/- 60 mm (80 µs echo)

Direct contact with fluid


Mounting options

  • Inline mounting: flange, mounting adaptor, vertical or horizontal

  • Inline installation in flowcell possible

  • Mounting in bassin possible


Cables

Sensor to dataprocessor: 2m, 6m (Other lenghts on request)
Dataprocessor to plc/datalogger: long cables possibles


Order & More information

All product variations

CUSTOM
Custom solutions possible
OBO-IWAA-001
Dry Solids (%DS) measurement in Iron water / Iron sludge
OBO-MLSA-001
MLSS / (activated) sludge concentration (Chain mounting)
OTD-MLSA-004
MLSS / (Activated) sludge concentration
OTD-MLSB-00X
MLSS / (Activated) sludge concentration (hot-tap transducer)
OTD-SDWA-00X
TSS (Sludge concentration) in sludge: 0 - 10% solids
OTD-SDWB-00X
TSS in dewatering centrate (Inline mounting)
OTD-SDWC-00X
Polymer concentration in centrate
OTD-SDWD-00X
Dry Solids in Sludge Cake: 0 - 40% DS
OTD-SDXA-00X
TSS (Sludge concentration) in sludge: 0 - 10% solids (with Hot-tap sensor)
OTD-SDXC-00X
Polymer concentration in centrate (extended hot-tap transducer)
OTD-TSSA-001
TSS concentration: 0 - 100 mg/L
OTD-TSSA-002
TSS concentration: 0 - 500 mg/L
OTD-TSSA-003
TSS concentration: 0 - 1.000 mg/L
OTD-TSSA-004
TSS concentration: 0 - 10.000 mg/L
OTE-CUSC-00X
Custom solution possible
OTE-SEDA-001
Olpas Sediment Load sensor
OTE-TSSC-001
Sonde, TSS concentration: 0 - 2 g/L
OTE-TSSC-002
Sonde, TSS concentration: 0 - 4 g/L
OTE-TSSC-003
Sonde, TSS concentration: 0 - 6 g/L
OTU-IWAA-001
Dry Solids Measurement in Iron Slude / Iron Water (Inline)
OTU-MLSA-001
MLSS / (activated) sludge concentration (Inline) : 0 - 20 g/L
OTU-SDXA-001
Sludge Concentration (inline mounting, hot tap transducer)
OTU-SDXB-001
TSS in dewatering centrate (Inline mounting)
OTU-SDXC-001
Polymer concentration in centrate (extended hot-tap transducer without screen and butons)
OTU-SDXD-001
Sludge Cake Concentration (inline mounting, SS316 transducer)
OTU-TSSB-001
TSS concentration (Inline mounting)

Didn't find what you're looking for ? 
With our versatile OLPAS Technology, we can build a tailor made sensor optimised for your application. 